Studer-innotec XTH 3000-12 Manuel d'utilisateur Page 25

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 24
Steca Xtender
Installation and Operating Instructions 723.932 Xtender V0.511 Seite 25
The features of the RCC-02 and the RCC-03 are the same. They only differ in their external
appearance. The RCC-02 is designed for wall mounting, whereas the RCC-03 is designed as a
tabletop device.
The RCC-03 model must be taken off the table to allow access to the SD card slot (during
updating, for example).
RCC-02: Dimensions: H x W x D / / 58 x 51.5 x 22 mm
RCC-03: Dimensions: H x W x D / / 58 x 51.5 x 22 mm
The two remote control models are delivered with a 2 m cable by default.
Cables of specific lengths (5 m, 20 m and 50 m) can be ordered.
The article no. is as follows: CAB-RJ45-xx. The length in metres is specified as xx
Up to 3 RCC-02/03 remote controls can be connected in series on the communication bus of one
Xtender or an Xtender multi-inverter system. In a system comprising a single Xtender, the
connection of the RCC-02 or RCC-03 may be conducted without stopping the Xtender (warm).
When connecting an RCC-02/03 remote control in a multi-unit system, it is recommended that all
units in the system be stopped and that the communication bus on the device on which the
connection is being made be terminated.
The 2 switches for terminating the communication bus, “Com. Bus" (4) both
remain in
position T (terminated) except when both
connectors are in use. In this case, and only in
this case, both must be placed in the O open position. If one of the two connectors is not
in use, the two termination switches (14) will be in position T.
6.4.2
BTS-01
TEMPERATURE SENSOR
The operating voltages for lead batteries vary depending on the
temperature. A temperature sensor is optionally available to correct the
battery voltage and guarantee an optimum charge whatever the battery
temperature. The correction factor given by the correction of the sensor
is set by the configuration {1139}
Article no. for the temperature sensor (including a cable of 3 m): BTS-01.
Dimensions: H x W x D / / 58 x 51.5 x 22 mm
Vue de la page 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 39 40

Commentaires sur ces manuels

Pas de commentaire